Floor Standing Lifting Stations

Sanicubic 2 GR HP

Ambient visual of a Sanicubic 2 GR HP S, single-phase, lifting station to be installed for grey/wastewater in the basement.

Sanicubic 2 GR HP

The Sanicubic 2 GR HP is a 2-motor lifting station, ideal for large homes and small commercial premises.
Installation without disbursement
Accessibility in case of maintenance
Max. permissible T° of pumped liquid up to 90 °C (5 min)
3 entrances including 2 low lateral
2 pumps with Pro X K2 dilacerator impeller
Alternating operation of the 2 pumps
Control box with audible and visual alarm
Remote wired alarm box included: for reporting the alarm signal
Find out more

Product details

Sanicubic 2 GR HP is a plant equipped with two motors, designed for the removal of wastewater from individual houses, apartments, small commercial structures, shops or restaurants.

It benefits from the Pro X K2 dilaceration technology allowing the evacuation of effluents through a pipe of small diameter 50mm. The two pumps work alternatively, and activate simultaneously in the event of a large intake.

The 3 inputs including the 2 bass allow great flexibility in the installation.

Sanicubic 2 GR HP comes standard with a control box incorporating an audible and visual alarm and a remote wired alarm box.

Product code: 30017
Technical specification

Sanicubic 2 GR HP

Materials

  • Shaft
  • Tank
  • Pump housing
  • Waterproofing
  • Motor housing
  • Impeller
  • Shaft
  • Shaft
  • Tank
  • Tank
  • Pump housing
  • Pump housing
  • Waterproofing
  • Waterproofing
  • Motor housing
  • Motor housing
  • Impeller
  • Impeller
  • Shaft
  • Stainless steel
  • Tank
  • PE HD
  • Pump housing
  • Steel
  • Waterproofing
  • NBR
  • Motor housing
  • Aluminium
  • Impeller
  • Copper

Electrical features

  • Number of motor(s)
  • Socket included
  • Voltage (V)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • IP Rating
  • Electrical class
  • Mode of operation
  • Current
  • Length of cable-control box (m)
  • Number of pumps
  • Type of control box
  • Length (m)
  • Section (mm²)
  • Type of cable
  • Number of motor(s)
  • Number of motor(s)
  • Socket included
  • Socket included
  • Voltage (V)
  • Voltage (V)
  • Frequency (Hz)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • Maximum current (A)
  • IP Rating
  • IP Rating
  • Electrical class
  • Electrical class
  • Mode of operation
  • Mode of operation
  • Current
  • Current
  • Length of cable-control box (m)
  • Length of cable-control box (m)
  • Number of pumps
  • Number of pumps
  • Type of control box
  • Type of control box
  • Length (m)
  • Length (m)
  • Section (mm²)
  • Section (mm²)
  • Type of cable
  • Type of cable
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 220-240
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 2500
  • Power output P2 (W)
  • 2000
  • Revolution per minute (RPM)
  • 2800
  • Maximum current (A)
  • 16
  • IP Rating
  • IPX8
  • Electrical class
  • I
  • Mode of operation
  • S3 40 %
  • Current
  • Single-phase
  • Length of cable-control box (m)
  • 4
  • Number of pumps
  • 2
  • Type of control box
  • Classic
  • Length (m)
  • 1,5
  • Section (mm²)
  • 1.5
  • Type of cable
  • H07 RN-F 3G

Hydraulics

  • Max. Head (Q0) (m)
  • Max. flow rate (m³/h)
  • Number of inlets
  • External inlet diameter (mm)
  • Discharge diameter DN
  • Ext. ventilation diameter (mm)
  • Total volume (L)
  • Useable volume (L)
  • ON Level (mm)
  • OFF level (mm)
  • Alarm level (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Medium (°C)
  • Type of impeller
  • Type of activation
  • Max. Head (Q0) (m)
  • Max. Head (Q0) (m)
  • Max. flow rate (m³/h)
  • Max. flow rate (m³/h)
  • Number of inlets
  • Number of inlets
  • External inlet diameter (mm)
  • External inlet diameter (mm)
  • Discharge diameter DN
  • Discharge diameter DN
  • Ext. ventilation diameter (mm)
  • Ext. ventilation diameter (mm)
  • Total volume (L)
  • Total volume (L)
  • Useable volume (L)
  • Useable volume (L)
  • ON Level (mm)
  • ON Level (mm)
  • OFF level (mm)
  • OFF level (mm)
  • Alarm level (mm)
  • Alarm level (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Medium (°C)
  • Medium (°C)
  • Type of impeller
  • Type of impeller
  • Type of activation
  • Type of activation
  • Max. Head (Q0) (m)
  • 18
  • Max. flow rate (m³/h)
  • 19
  • Number of inlets
  • 2
  • External inlet diameter (mm)
  • 100
  • Discharge diameter DN
  • 32
  • Ext. ventilation diameter (mm)
  • 50
  • Total volume (L)
  • 39
  • Useable volume (L)
  • 15
  • ON Level (mm)
  • 155
  • OFF level (mm)
  • 60
  • Alarm level (mm)
  • 225
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 90°C
  • Medium (°C)
  • 35
  • Type of impeller
  • Pro X K2 grinder
  • Type of activation
  • pneumatic

Logistics

  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • 39

Dimensions

  • Height (mm)
  • Product width (mm)
  • Length (mm)
  • Height (mm)
  • Height (mm)
  • Product width (mm)
  • Product width (mm)
  • Length (mm)
  • Length (mm)
  • Height (mm)
  • 400
  • Product width (mm)
  • 660
  • Length (mm)
  • 518

General description

  • EAN code
  • EAN code
  • EAN code
  • EAN code
  • 3308815090122
Quality

Buy with confidence

  • Performance and Reliability

    Technologies and materials that ensure efficiency and longevity.

  • Made in France

    Most of our products are manufactured in France to the highest quality standards.

  • Warranty Extension

    Saniflo products can be registered for a warranty of up to 5 years.

  • Extensive support

    A network of Approved Service Engineers.

  • Experts Since 1958

    Creator of the Saniflo macerating toilet.