Floor Standing Lifting StationsSanicubic 2 GR HP
Ambient visual of a Sanicubic 2 GR HP S, single-phase, lifting station to be installed for grey/wastewater in the basement.

Sanicubic 2 GR HP

The Sanicubic 2 GR HP is a 2-motor lifting station, ideal for large homes and small commercial premises.
Installation without disbursement
Accessibility in case of maintenance
Max. permissible T° of pumped liquid up to 90 °C (5 min)
3 entrances including 2 low lateral
2 pumps with Pro X K2 dilacerator impeller
Alternating operation of the 2 pumps
Control box with audible and visual alarm
Remote wired alarm box included: for reporting the alarm signal
Find out more

Product details

Sanicubic 2 GR HP is a plant equipped with two motors, designed for the removal of wastewater from individual houses, apartments, small commercial structures, shops or restaurants.

It benefits from the Pro X K2 dilaceration technology allowing the evacuation of effluents through a pipe of small diameter 50mm. The two pumps work alternatively, and activate simultaneously in the event of a large intake.

The 3 inputs including the 2 bass allow great flexibility in the installation.

Sanicubic 2 GR HP comes standard with a control box incorporating an audible and visual alarm and a remote wired alarm box.

Product code: 30017

Please note that this Sanicubic will be replaced with a new ‘L’ version by 1st May 2026.

The new version will be exactly the same in terms of design and performance, however the wired alarm will no longer be provided as standard. The wired alarm will still be available to purchase separately.
Technical specification

Sanicubic 2 GR HP

Materials

  • Shaft
  • Tank
  • Pump housing
  • Seal
  • Motor housing
  • Impeller
  • Shaft
  • Shaft
  • Tank
  • Tank
  • Pump housing
  • Pump housing
  • Seal
  • Seal
  • Motor housing
  • Motor housing
  • Impeller
  • Impeller
  • Shaft
  • Stainless steel
  • Tank
  • PE HD
  • Pump housing
  • PP GF
  • Seal
  • NBR
  • Motor housing
  • Aluminium
  • Impeller
  • PP GF

Electrical features

  • Number of motor(s)
  • Socket included
  • Voltage (V)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • IP rating
  • Electrical class
  • Mode of operation
  • Current
  • Length of cable-control box (m)
  • Number of pumps
  • Type of control box
  • Length (m)
  • Section (mm²)
  • Type of cable
  • Number of motor(s)
  • Number of motor(s)
  • Socket included
  • Socket included
  • Voltage (V)
  • Voltage (V)
  • Frequency (Hz)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • Maximum current (A)
  • IP rating
  • IP rating
  • Electrical class
  • Electrical class
  • Mode of operation
  • Mode of operation
  • Current
  • Current
  • Length of cable-control box (m)
  • Length of cable-control box (m)
  • Number of pumps
  • Number of pumps
  • Type of control box
  • Type of control box
  • Length (m)
  • Length (m)
  • Section (mm²)
  • Section (mm²)
  • Type of cable
  • Type of cable
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 220-240
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 2500
  • Power output P2 (W)
  • 2000
  • Revolution per minute (RPM)
  • 2800
  • Maximum current (A)
  • 16
  • IP rating
  • IPX8
  • Electrical class
  • I
  • Mode of operation
  • S3 40 %
  • Current
  • Single-phase
  • Length of cable-control box (m)
  • 4
  • Number of pumps
  • 2
  • Type of control box
  • Classic
  • Length (m)
  • 1,5
  • Section (mm²)
  • 1.5
  • Type of cable
  • H07 RN-F 3G

Hydraulic

  • Max. Head (m)
  • Max. flow rate (m³/h)
  • Number of inlets
  • External inlet diameter (mm)
  • Discharge diameter ext. (mm)
  • Ext. ventilation diameter (mm)
  • Total volume (L)
  • Useable volume (L)
  • ON Level (mm)
  • OFF level (mm)
  • Alarm level (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Type of impeller
  • Type of activation
  • Max. Head (m)
  • Max. Head (m)
  • Max. flow rate (m³/h)
  • Max. flow rate (m³/h)
  • Number of inlets
  • Number of inlets
  • External inlet diameter (mm)
  • External inlet diameter (mm)
  • Discharge diameter ext. (mm)
  • Discharge diameter ext. (mm)
  • Ext. ventilation diameter (mm)
  • Ext. ventilation diameter (mm)
  • Total volume (L)
  • Total volume (L)
  • Useable volume (L)
  • Useable volume (L)
  • ON Level (mm)
  • ON Level (mm)
  • OFF level (mm)
  • OFF level (mm)
  • Alarm level (mm)
  • Alarm level (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Type of impeller
  • Type of impeller
  • Type of activation
  • Type of activation
  • Max. Head (m)
  • 18
  • Max. flow rate (m³/h)
  • 19
  • Number of inlets
  • 2
  • External inlet diameter (mm)
  • 100
  • Discharge diameter ext. (mm)
  • 50
  • Ext. ventilation diameter (mm)
  • 50
  • Total volume (L)
  • 39
  • Useable volume (L)
  • 15
  • ON Level (mm)
  • 155
  • OFF level (mm)
  • 60
  • Alarm level (mm)
  • 225
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 90°C
  • Type of impeller
  • Pro X K2 grinder
  • Type of activation
  • pneumatic

Logistics

  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • 39

General description

  • EAN code
  • EAN code
  • EAN code
  • EAN code
  • 3308815090122
Quality

Buy with confidence

  • Performance and Reliability

    Technologies and materials that ensure efficiency and longevity.

  • Made in France

    Most of our products are manufactured in France to the highest quality standards.

  • Warranty Extension

    Saniflo products can be registered for a warranty of up to 5 years.

  • Extensive support

    A network of Approved Service Engineers.

  • Experts Since 1958

    Creator of the Saniflo macerating toilet.