Floor Standing Lifting Stations

Sanicubic 2 Pro

Ambient visual of a Sanicubic 2 Pro, lifting station for grey/black water installed on the ground in a garage.

Sanicubic 2 Pro

The Sanicubic 2 Pro is a high performance macerator pump for commercial use. It contains two separate, load balanced pumps with high performance macerating systems and will operate alternatively. In the event of inflow overload, both motors run at the same time or in the unlikely event that one motor fails, the other one will take over.
Takes waste from WC’s, basin, bath, shower, bidet, washing machine, dishwasher and sink.
Tough, reliable macerator ideal for busy business environments and commercial situations
New design with easily removable motor for servicing and maintenance
Pumps vertically 13m
Find out more

Product details

The Sanicubic 2 Pro is a tough, reliable macerator pump which contains two separate load balanced macerator systems which operate alternately ensuring even wear of motors. It is ideal for busy business and commercial situations. The unit can handle waste water from WC’s, a basin, sink, washing machine, dishwasher, shower, bath, and bidet. The Sanicubic 2’s new design means the motors are easily removable for servicing and maintenance as is the water level indicator. It has two alarms for ultimate safety a hard-wired alarm and a remote wireless alarm. The Sanicubic 2 Pro has four inlets, the centre height of inlets is 140mm and it discharges through 50 mm pipework. It has a working temperature of 35ºC, however it will handle temperatures up to 75ºC for short periods. The Sanicubic 2 has a tank capacity of 45 litres and a flow rate 13m³/h. It can be connected to a Building Management System. The Sanicubic 2 Pro comes with a 2 year warranty.

Designed, made and tested in our factory in France and with 60 years of expertise and innovation, the Sanicubic 2 offers you peace of mind and with the back-up from our service team there’s never been a better time to install a Saniflo.

Product codes: 30011, 30012, 20013
Technical specification

Sanicubic 2 Pro

  • Version
  • Version
  • Version
  • Version
  • Sanicubic 2 Pro
  • Version
  • Sanicubic 2 Pro Smart
  • Version
  • Sanicubic 2 Pro Smart Brushless

Materials

  • Shaft
  • Tank
  • Pump housing
  • Waterproofing
  • Motor housing
  • Impeller
  • Shaft
  • Shaft
  • Tank
  • Tank
  • Pump housing
  • Pump housing
  • Waterproofing
  • Waterproofing
  • Motor housing
  • Motor housing
  • Impeller
  • Impeller
  • Shaft
  • Stainless steel
  • Tank
  • PP
  • Pump housing
  • Steel
  • Waterproofing
  • NBR
  • Motor housing
  • PA 12 GF
  • Impeller
  • Copper
  • Shaft
  • Stainless steel
  • Tank
  • PP
  • Pump housing
  • Steel
  • Waterproofing
  • NBR
  • Motor housing
  • PA 12 GF
  • Impeller
  • Copper
  • Shaft
  • Stainless steel
  • Tank
  • PP
  • Pump housing
  • Steel
  • Waterproofing
  • NBR
  • Motor housing
  • PA 12 GF
  • Impeller
  • Copper

Electrical features

  • Number of motor(s)
  • Socket included
  • Voltage (V)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • IP Rating
  • Electrical class
  • Motor insulation class
  • Mode of operation
  • Current
  • Length of cable-control box (m)
  • Number of pumps
  • Type of control box
  • Length (m)
  • Section (mm²)
  • Type of cable
  • Number of motor(s)
  • Number of motor(s)
  • Socket included
  • Socket included
  • Voltage (V)
  • Voltage (V)
  • Frequency (Hz)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • Maximum current (A)
  • IP Rating
  • IP Rating
  • Electrical class
  • Electrical class
  • Motor insulation class
  • Motor insulation class
  • Mode of operation
  • Mode of operation
  • Current
  • Current
  • Length of cable-control box (m)
  • Length of cable-control box (m)
  • Number of pumps
  • Number of pumps
  • Type of control box
  • Type of control box
  • Length (m)
  • Length (m)
  • Section (mm²)
  • Section (mm²)
  • Type of cable
  • Type of cable
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 220-240
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 1500
  • Power output P2 (W)
  • 1050
  • Revolution per minute (RPM)
  • 2800
  • Maximum current (A)
  • 13
  • IP Rating
  • IP68
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Mode of operation
  • S3 50 %
  • Current
  • Single-phase
  • Length of cable-control box (m)
  • 4
  • Number of pumps
  • 2
  • Type of control box
  • Classic
  • Length (m)
  • 2,5
  • Section (mm²)
  • 1.5
  • Type of cable
  • H07 RN-F 3G
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 220-240
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 1500
  • Power output P2 (W)
  • 1050
  • Revolution per minute (RPM)
  • 2800
  • Maximum current (A)
  • 13
  • IP Rating
  • IP68
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Mode of operation
  • S3 50 %
  • Current
  • Single-phase
  • Length of cable-control box (m)
  • 4
  • Number of pumps
  • 2
  • Type of control box
  • Smart
  • Length (m)
  • 2,5
  • Section (mm²)
  • 1.5
  • Type of cable
  • H07 RN-F 3G
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 220-240
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 1500
  • Power output P2 (W)
  • 1050
  • Revolution per minute (RPM)
  • 2800
  • Maximum current (A)
  • 13
  • IP Rating
  • IP68
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Mode of operation
  • S3 50 %
  • Current
  • Single-phase
  • Length of cable-control box (m)
  • 4
  • Number of pumps
  • 2
  • Type of control box
  • Smart
  • Length (m)
  • 2,5
  • Section (mm²)
  • 1.5
  • Type of cable
  • H07 RN-F 3G

Hydraulics

  • Max. Head (Q0) (m)
  • Max. flow rate (m³/h)
  • Number of inlets
  • External inlet diameter (mm)
  • Discharge diameter ext. (mm)
  • Ext. ventilation diameter (mm)
  • Total volume (L)
  • Useable volume (L)
  • ON Level (mm)
  • OFF level (mm)
  • Alarm level (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Medium (°C)
  • Type of impeller
  • Type of activation
  • Max. Head (Q0) (m)
  • Max. Head (Q0) (m)
  • Max. flow rate (m³/h)
  • Max. flow rate (m³/h)
  • Number of inlets
  • Number of inlets
  • External inlet diameter (mm)
  • External inlet diameter (mm)
  • Discharge diameter ext. (mm)
  • Discharge diameter ext. (mm)
  • Ext. ventilation diameter (mm)
  • Ext. ventilation diameter (mm)
  • Total volume (L)
  • Total volume (L)
  • Useable volume (L)
  • Useable volume (L)
  • ON Level (mm)
  • ON Level (mm)
  • OFF level (mm)
  • OFF level (mm)
  • Alarm level (mm)
  • Alarm level (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Medium (°C)
  • Medium (°C)
  • Type of impeller
  • Type of impeller
  • Type of activation
  • Type of activation
  • Max. Head (Q0) (m)
  • 13
  • Max. flow rate (m³/h)
  • 15
  • Number of inlets
  • 5
  • External inlet diameter (mm)
  • 40, 50, 100, 110
  • Discharge diameter ext. (mm)
  • 50
  • Ext. ventilation diameter (mm)
  • 50
  • Total volume (L)
  • 45
  • Useable volume (L)
  • 17,5
  • ON Level (mm)
  • 140
  • OFF level (mm)
  • 70
  • Alarm level (mm)
  • 210
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 70°C
  • Medium (°C)
  • 35
  • Type of impeller
  • Pro X K2 grinder
  • Type of activation
  • pneumatic
  • Max. Head (Q0) (m)
  • 13
  • Max. flow rate (m³/h)
  • 15
  • Number of inlets
  • 5
  • External inlet diameter (mm)
  • 100, 110, 40, 50
  • Discharge diameter ext. (mm)
  • 50
  • Ext. ventilation diameter (mm)
  • 50
  • Total volume (L)
  • 45
  • Useable volume (L)
  • 17,5
  • ON Level (mm)
  • 140
  • OFF level (mm)
  • 70
  • Alarm level (mm)
  • 210
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 70°C
  • Medium (°C)
  • -
  • Type of impeller
  • Pro X K2 grinder
  • Type of activation
  • pneumatic
  • Max. Head (Q0) (m)
  • 13
  • Max. flow rate (m³/h)
  • 15
  • Number of inlets
  • 5
  • External inlet diameter (mm)
  • 40, 100, 50, 110
  • Discharge diameter ext. (mm)
  • 50
  • Ext. ventilation diameter (mm)
  • 50
  • Total volume (L)
  • 45
  • Useable volume (L)
  • 17,5
  • ON Level (mm)
  • 140
  • OFF level (mm)
  • 70
  • Alarm level (mm)
  • 210
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 70°C
  • Medium (°C)
  • -
  • Type of impeller
  • Pro X K2 grinder
  • Type of activation
  • pneumatic

Logistics

  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • 34
  • Gross weight (kg)
  • 35
  • Gross weight (kg)
  • 35

Dimensions

  • Height (mm)
  • Product width (mm)
  • Length (mm)
  • Weight (kg)
  • Height (mm)
  • Height (mm)
  • Product width (mm)
  • Product width (mm)
  • Length (mm)
  • Length (mm)
  • Weight (kg)
  • Weight (kg)
  • Height (mm)
  • 490
  • Product width (mm)
  • 516
  • Length (mm)
  • 687
  • Weight (kg)
  • 31
  • Height (mm)
  • 490
  • Product width (mm)
  • 516
  • Length (mm)
  • 687
  • Weight (kg)
  • 33
  • Height (mm)
  • 495
  • Product width (mm)
  • 517
  • Length (mm)
  • 657
  • Weight (kg)
  • -

General description

  • EAN code
  • EAN code
  • EAN code
  • EAN code
  • 3308815074450
  • EAN code
  • 3308815075457
  • EAN code
  • 3308815085166
Quality

Buy with confidence

  • Performance and Reliability

    Technologies and materials that ensure efficiency and longevity.

  • Made in France

    Most of our products are manufactured in France to the highest quality standards.

  • Warranty Extension

    Saniflo products can be registered for a warranty of up to 5 years.

  • Extensive support

    A network of Approved Service Engineers.

  • Experts Since 1958

    Creator of the Saniflo macerating toilet.